Sunboost is a high-tech enterprise focusing on the R&D, manufacturing and sales of energy storage battery and solar power inverter.
This picture is for reference only, subject to the real thing !
MODEL: TG-HYB-3600
Recommend max.PV input power: 8700Wp
Max.PV input voltage: 600V
Min.operation/Start-up Voltage: 40V/50V
Ated PV input voltage: 360V
MPPT Voltage Range: 40-560V
No.of independent MPPT inputs: 2
Products Advantages
- 10 years Warranty.
- Max. PV input current 16A: compatible across All Power Ranges of Solar Panels.
- UPS Mode: Seamless transition to backup mode to assure an uninterrupted power supply.
- Wide PV input range : 40-600 Vdc, 40V means one single solar pane lcan make it work.
- Twice Of Energy Potential : PV Input Power is Twice Of ACOutput Power, enabling more solar energy input.
- Protection: Anti-islanding Protection, Insula-tion Resistance Detection and Leakage monitoring protection.
Product Specifications
Single Phase Hybrid Inverter-TG-HYB | ||||||
MODEL TG-HYB-3600 TG-HYB-5000 TG-HYB-6000 | ||||||
PV INPUT(DC) | ||||||
Recommend max.PV input power 8700Wp | 10000Wp | 11000Wp | ||||
Max.PV input voltage | 600V | |||||
Min.operation/Start-up Voltage | 40V/50V | |||||
ated PV input voltage | 360V | |||||
MPPT Voltage Range | 40-560V | |||||
No.of independent MPPT inputs | 2 | |||||
Max. PV input current | 16A | |||||
Max. DC short-circuit current | 20A | |||||
INPUT/OUTPUT(AC) | ||||||
Max.AC input power from grid | 8700VA | 10000VA | 11000VA | |||
Rated AC output power | 3680W | 5000W | 6000W | |||
Rated AC output current (at 230V) | 16A | 21.8A | 26. 1A | |||
Rated AC voltage | 220V/230V/240V | |||||
AC voltage range | 154V~276V | |||||
Rated grid frequency | 50Hz/60Hz | |||||
Grid frequency range | 45~55Hz/55~65Hz | |||||
EFFICIENCY | ||||||
Max.efficiency | 97.70% | |||||
European efficiency | 97.30% | |||||
PROTECTION&FUNCTION | Grid monitoring/DC reverse polarity protection/AC short circuit protection/Leakage current protec- tion /DCs witch(PV)/DC fuse(battery)/Battery input reverse polarity protection |
|||||
SurgeProtection | DC typeⅡ/AC typeⅡ | |||||
BATTERY DATA | ||||||
Battery Type | Li-ion battery | |||||
Battery voltage | 40-59V | |||||
Max.charge/discharge current | 100A | |||||
Max.charge/discharge power | 5000W | |||||
GENERAL DATA | ||||||
Dimensions(W*H*D) | 600*365*180mm | |||||
Weight | ≤25kg | |||||
Degree of protection | IP65 | |||||
Operating ambient temperature range | -25℃~60℃ | |||||
BACKUP DATA(ONGRIDMODEL) | ||||||
Rated | output power for backup load | 6000W | ||||
Rated | output current for backup load | 27A | ||||
BACKUP DATA(OFF GRID MODEL) | ||||||
Rated voltage | 220V/230V/240V(±2%) | |||||
Frequency range | 50Hz/60Hz(±0.5%) | |||||
Switch time to emergency model | ≤10ms | ≤10ms | ≤10ms | |||
Rated output power | 3680W/3680VA | 5000W/5000VA | 6000W/6000VA | |||
Peak output power | 8400VA, 10s | |||||
Certifications and Standards | ||||||
Grid Regulation | EN50549- 1, EN50549- 10, PTPiREE, NCRFG, VDE4105, AS/NZS 4777.2, NRS-097-2- 1 | |||||
Safety Regulation | IEC62109- 1&2, EN62109- 1&2 | |||||
EMC | EN61000-6- 1, EN61000-6-3, IEC61000-6- 1, IEC61000-6-3 |